1 node address setting, Node address setting – Lenze 931K User Manual
Page 21

Commissioning
Settings on the controller (slave)
Node address setting
l
21
KHB 13.0004−EN 2.1
6.3.1
Node address setting
Selecting the node address via »Small Drives Control (SDC)«
1. Open the Parameters
W Fieldbus W Profibus... W Operating parameters... menu.
931E_020, 931E_21
2. Enter the desired node address for the controller in the Slave node number input
box.
3. Tick the Profibus active check box.
– If the check box is enabled, the Slave node number input box is disabled.
4. Click on the Save & Reset button to save the settings.
– After saving, the assigned node address is displayed in the Effective slave node
number box.
5. Click on the OK button.
)
Note!
The dialog box displays that the communication between master and slave
has been established successfully:
ƒ
The Data Exchange box is lit green.
ƒ
The baud rate set on the master is displayed in the Baud rate box.