10 appendix, 1 table of parameter numbers (pnu), Appendix – Lenze 931K User Manual
Page 66: Table of parameter numbers (pnu), How to read the table

Appendix
Table of parameter numbers (PNU)
10
l
66
KHB 13.0004−EN 2.1
10
Appendix
10.1
Table of parameter numbers (PNU)
ƒ
The PNUs are numerically sorted in ascending order to form a "reference book".
ƒ
How to read the table:
Column
Abbreviation
Meaning
PNU
XXXX
Parameter number XXXX
1
Subindex 1 of PNU XXXX (PNU XXXX.1)
2
Subindex 2 of PNU XXXX (PNU XXXX.2)
Name
Name of the PNU
Possible settings
Lenze
Lenze setting (value at delivery or after restoring the delivery state)
Selection
1
{%}
99 Minimum value
{unit} maximum value
Characteristics
Object type
REC
Record
ARR
Array, composed type (field)
VAR
Variable
Data type
UINT8
Unsigned integer, 1 byte without sign
UINT16
Unsigned integer, 2 bytes without sign
UINT32
Unsigned integer, 4 bytes without sign
INT8
Integer, 1 byte with sign
INT16
Integer, 2 bytes with sign
INT32
Integer, 4 bytes with sign
Access
RO
Read only
RW
Read/write
WO
Write only
Description
Short, important explanations
PNU
Name
Possible settings
Characteristics
Lenze
Selection
Description
930
0 Operating Mode
Ċ
UINT16
RO
Ċ
00
h
Speed control
Reading−out of the operating
mode.
10
h
Positioning
967
0 Control word 1
0
Ċ
UNIT16
RW
Ċ
Control of the device
functions of the controller
968
0 Status word 1
0
Ċ
UNIT16
RO
Ċ
Current state of the
controller
971
0 Transfer into a
non−volatile
memory
0
Ċ
UNIT16
RW
Ċ
0
No action
Save current parameter set
and all position data sets
Also saves position data set
68.
1
Save
2 ... 655
35
Reserved