Appendix, Table of parameter numbers (pnu) – Lenze 931K User Manual
Page 70

Appendix
Table of parameter numbers (PNU)
l
70
KHB 13.0004−EN 2.1
Characteristics
Possible settings
Name
PNU
Description
Selection
Lenze
Name
PNU
1051
0 Home Offset
0
−32767
{1 inc}
32767
Ċ
INT32
RW
Ċ
Definition of the distance
between the zero position
and the reference point of a
homing sequence.
l
Positive values shift the
zero point to the positive
direction with respect to
the reference point.
1100
0 Position Actual
Value
{1 inc}
Ċ
INT32
RO
Ċ
Actual position value. The
value is scaled to the physical
unit set for PROFIBUS.
1101
0 Velocity Actual
Value
{1 rpm}
Ċ
INT32
RO
Ċ
Actual speed value. The value
is scaled to the physical unit
set for PROFIBUS.
1102
0 Current Actual
Value
{1 }
Ċ
INT32
RO
Ċ
Actual value of active
current. The value refers to
the rated motor current.
1140
0 Digital Outputs
0
Ċ
UINT32
RW
Ċ
Bit
Value
Triggering of the digital
outputs.
Important! Up to 10 ms may
pass between triggering and
switching of the output.
The state of an output can be
checked by reading out the
parameter.
0
00000001
h
Holding brake
(read only)
1 ... 15
Reserved
16
00010000
h
Ready for
operation (read
only)
17, 18
00060000
h
DOUT1, DOUT2
(read and write)
19 ... 32
Reserved
1141
0 Digital Inputs
0
Ċ
UINT32
RO
Ċ
Bit
Value
Actual states of the digital
inputs.
The available digital inputs
depend on the
parameterisation of the
controller
0
00000001
h
Negative limit
switch (DIN7)
1
Reserved
2
00000002
h
Positive limit
switch (DIN7)
3
00000008
h
Controller enable
is missing (DIN9)
16 ... 25
03FF0000
h
DIN0 ... DIN9
26 ... 32
Reserved