7 parameter setting, 1 physical units, Parameter setting – Lenze 931K User Manual
Page 43: Physical units, 7parameter setting

Parameter setting
Physical units
7
l
43
KHB 13.0004−EN 2.1
7
Parameter setting
7.1
Physical units
)
Note!
Application−specific parameters depend on the physical units. For this reason
set the physical units before starting to parameterise the application.
With the »Small Drives Control (SDC)« program you can parameterise the controller in such
a way that the physical quantities can be entered/read out on the drive directly in the
desired units (e.g. position values of a linear axis in millimetres and speeds in millimetres
per second).
ƒ
Open the Parameters
W Fieldbus W Profibus... W Display units... menu.
931E_026
Quantity
Designation
Unit
Explanation
Length
position_units
Increments
65535 increments per revolution
Speed
speed_units
rpm
Revolutions per minute
Acceleration
acceleration_units
rpm/s
Speed increase per second