Operation

Control Panel Applets

MPI Configuration

8

l

51

LDCDS−EL100 EN 9.0

8.2.7

MPI Configuration

EL100−029

This Applet is only relevant for an EL 1xx MPI.

HSA: Set the highest MPI address (Highest Station Address) here. The highest MPI address
must be identical within an MPI network!

TS (This Station): Set the local MPI address for the EL 1xx here.

Baud Rate: Transmission speed of the MPI network. The baud rate must be identical for
each MPI node within the same network. The MPI parameters are set according to the baud
rate.

Default Net Parameters: Default Net Parameters specified due to the baud rate. We
recommend not to modify them.

Status: The status of the MPI interface is displayed as "Offline", "Online" or "Error" in the
status bar.

See VisiWinNET

â

Smart software manual for further information.

8.2.8

CAN Gateway

The CAN gateway function is used to implement data transmission from an Ethernet
network to the Lenze "CAN system bus" fieldbus. The following functions are supported:

ƒ

Data transmission via SDO

ƒ

Parameter data exchange

ƒ

Program download from PC to Lenze drive components

Communication between the PC and the Lenze drive components connected to the CAN
system bus is possible via the following programs:

ƒ

DriveServer, Global Drive Control, Global Drive Loader

ƒ

Global Drive PLC Developer−Studio

ƒ

L−force Engineer

)

Note!

The CAN gateway function is only supported if CAN communication software
from version 2.2.2.0 is installed on the PC.

Further information is provided elsewhere in this manual (

78).