Lenze · Controller-based Automation - Visualisation · System Manual · DMS 1.5 EN · 04/2014 · TD17

33

4

System description

4.3

Network topologies

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Stand-alone application

( 16)

Integrated control system

( 17)

Remote access

Remote access allows you to separate the control system and visualisation on physically separated

IPCs. The system structure is basically similar to a

Client/server system

( 18)

.

• Remote access may be reasonable if a control system runs on a control cabinet PC, but no

monitor is available. In contrast to the client/server system, it is not possible to implement

several operator terminals.

• Depending on the fieldbus, direct drivers (optimised for remote access) or remote-capable OPC

servers can be used.

Channels

( 32)

Direct drivers...

OPC servers...

• are contained in the scope of supply of the

»VisiWinNET®« development packages.

• are transferred from the Engineering PC to the

Industrial PC when the visualisation application is

downloaded.

• are specially tailored to »VisiWinNET®« and can only

be used for this software program.

• can be universally used and offer an open interface.

Like this, it is basically possible to integrate other

control or bus systems into »VisiWinNET®« if a

suitable OPC server is available.

• usually must be installed separately.