Kinze 3000 Rigid Frame Planter Rev. 6/14 User Manual
Page 68

M0188-01
Model 3000
5-10
Rev. 6/11
TM
Rate Charts
LIqUID FERTILIzER SqUEEzE PUMP APPLICATION RATES
GALLONS PER ACRE
Drive
Driven
30" Rows 36" Rows 38" Rows
Drive
Driven
30" Rows 36" Rows
32" Rows
15
*62
6.9
5.8
5.5
46
*62
21.2
17.7
16.7
19
*62
8.8
7.3
6.9
15
19
22.5
18.8
17.8
15
46
9.3
7.8
7.4
32
34
26.9
22.4
21.2
19
46
11.8
9.8
9.3
34
32
30.3
25.3
24.0
15
34
12.6
10.5
9.9
19
15
36.2
30.1
28.6
15
32
13.4
11.2
10.6
46
34
38.6
32.2
30.5
32
*62
14.7
12.3
11.6
46
32
41.0
34.2
32.4
19
34
16.0
13.3
12.6
32
19
48.1
40.1
38.0
19
32
17.0
14.1
13.4
34
19
51.1
42.6
40.3
32
46
19.9
16.6
15.7
*62
34
52.1
43.4
41.1
34
46
21.1
17.6
16.7
*Optional sprocket.
Above chart is for planters equipped with contact drive. Check tires for correct operating pressure.
Chart calculated based on a solution weighing ten pounds per gallon.
NOTE: Fertilizer application rates can vary from the above chart. To prevent application miscalculations, make
field checks to be sure you are applying fertilizer at the desired rate.
To check the exact number of gallons your fertilizer attachment will actually deliver on a 30" row spacing:
1. Remove hose from one fertilizer opener and insert it into a collection container secured planter frame.
2. Engage fertilizer attachment and drive forward for 174'.
3. Measure fluid ounces caught in container and multiply by 100. Divide that amount by 128. Result is gallons of
fertilizer delivered per acre when planting in 30" rows.
4. Rinse collection container and repeat test on other rows if necessary. To convert delivery rate for wider rows,
multiply by following conversion factors:
36" multiply by 0.83
38" multiply by 0.79