Glue, 9well to pump connection (suction pipe) – Flint & Walling CPJS Shallow Well User Manual
Page 9
![background image](/manuals/560819/9/background.png)
9
WELL TO PUMP CONNECTION (SUCTION PIPE)
IL1392
Glue
3
3. The use of a union (optional) will assist with easy
connection and disconnect. (Fig. 3)
IL1346
Glue
2
2. Make the connection to your well. Wrap all threaded
fittings with pipe tape 5 times or apply a pipe paste (pipe
dope) to ensure an air tight connection. (Fig. 2)
1. Attach ejector to face of pump with two (2) bolts and
gasket provided. Venturi tube on the ejector inserts into
the top tapping of the face of the pump (Fig. 1).
IL1324
Priming Port
Venturi
Tube
This Side
Up
Ejector
1
4a. NOTE: For drilled (cased) wells, a foot valve is
required in the well at the end of the pipe to maintain
prime. (Fig 4a)
IL1187
Water Level
25 ft.
Max
Suction
Lift
3/4 or 1 in.
Discharge Pipe
1-1/4 in.
Suction
Pipe
Discharge
to Home
Pipe
Support
Foot Valve
4a