PUMP ELECTRICAL CONNECTIONS
3. Insert an electrical wire strain relief into the opening
in the side of the pressure switch closest to the motor.
(
Fig. 3)
IL1372
3
IL1373
Wire from
motor
4
IL1374
Wire from
motor
5
IL1375
Wire from
motor
Ground Screws
6
6. Connect the green ground wire from the motor cable
to one of the green ground screws at the bottom of the
pressure switch. (
Fig. 6)
5. Connect the two motor wires of the motor cable to the
two inside terminals on the pressure switch. (
Fig. 5)
4. Thread the cable from the pump motor through the
strain relief into the pressure switch cavity and tighten
both screws on the strain relief. Do not crush wire.
(