PUMP PRIMING & STARTUP

Deep Well Application Only:

CAUTION: All pumps must be primed (filling the

cavity with water) before they are first operated. This

may take several gallons of water, as the suction line will

be filled in addition to the pump cavity.
1. Remove the 1/2” priming plug. (

Fig. 1)

IL1407

1

IL1406

2

2. Fill pump cavity with water until full and replace

priming plug. (

Fig. 2)

IL1409

3

3. Tighten flow control screw completely by turning

clockwise, then loosen two turns. Now start the pump.

(

Fig. 3)

IL1408

Pressure

Gauge

4

4. If pump is properly primed, pressure will quickly build

and register on the gauge mounted directly on the

pump body. If pressure does not build repeat priming

operation. All air must be vented from the drive and

suction pipes as well as the body before the pump will

prime. The pump body may need to be filled several

times in order to achieve the prime. (

Fig. 4)