TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Little or no

discharge

1. Casing not initially filled with water

1. Fill pump casing

2. Suction lift too high, or too long

2. Move pump closer to water source

3. Hole or air leak in suction line

3. Repair or replace. Use pipe tape and pipe

sealing compound

4. Foot valve too small

4. Match foot valve to piping or install one size

larger foot valve.

5. Foot valve or suction line not submerged deep

enough in water

5. Submerge lower in water

6. Motor wired incorrectly

6. Check wiring diagram

7. Casing gasket leaking

7. Replace

8. Suction or discharge line valves closed

8. Open

Pump will not

deliver water or

develop pressure

1. No priming water in casing

1. Fill pump casing

2. Leak in suction line

2. Repair or replace

3. Discharge line is closed and priming air has

nowhere to go

3. Open ball valve

4. Suction line (or valve) is closed

4. Open

5. Foot valve is leaking

5. Replace foot valve

6. Suction screen clogged

6. Clean or replace

Loss of suction

1. Air leak in suction line

1. Repair or replace

2. Suction lift too high

2. Lower suction lift, install foot valve and prime

3. Insufficient inlet pressure or suction head

3. Increase inlet pressure by adding more water

to tank or increasing back pressure

4. Clogged foot valve or strainer

4. Unclog

Pump vibrates

and/or makes

excessive noise

1. Mounting plate or foundation not rigid enough 1. Reinforce
2. Foreign material in pump

2. Disassemble pump and clean

3. Impeller damaged

3. Replace

4. Worn motor bearings

4. Replace

Pump will not start

or run

1. Improperly wired

1. Check wiring diagram on motor

2. Blown fuse or open circuit breaker

2. Replace fuse or close circuit breaker

3. Loose or broken wiring

3. Tighten connections, replace broken wiring

4. Stone or foreign object lodged in impeller

4. Disassemble pump and remove foreign object

5. Motor shorted out

5. Replace

6. Thermal overload has opened circuit

6. Allow unit to cool, restart after reason for

overload has been determined