Flint & Walling CPJS Shallow Well User Manual
Page 13
13
TANK TO HOUSE CONNECTION
1. Most pressure tanks will have a 1 inch inlet elbow on
the bottom. Connect to this elbow with a 1 in. MPT x 1
in. slip (glue) adapter and short piece of pipe. (
Fig 1)
2. Install a 1 in. elbow. (
Fig. 2)
IL1365
Glue
Adapter
Pipe
1
IL1366
Glue
Elbow
2
5. Continue with fittings and pipe to the pressure tank.
A 3/4 in. union is optional but recommended for easy
connection and disconnection. (
Fig. 5)
CAUTION: Install a pressure relief valve on any
installation where the pump pressure can exceed the
maximum working pressure of the tank.
IL1387
Glue
5
PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)
This manual is related to the following products: