Glue – Flint & Walling CPJS Shallow Well User Manual
Page 11
11
PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)
Shallow Well Application Only:
1. Begin the connection to the pressure tank. Using a 3/4
in. x 3 in. galvanized nipple, wrap the threads 5 times
with pipe tape and apply pipe paste (pipe dope) and
install in top of pump.
(
Fig. 1)
4. Continue with fittings and pipe to the pressure tank.
A 3/4 in. union (optional) for easy connection and
disconnection. (
Fig. 4)
Glue
IL1400
IL1397
1
IL1398
2
IL1399
3
3. Install a 3/4 in. MPT x 1/4 in. FPT galvanized bushing
and pressure gauge (optional), or a pipe plug. Do
not tighten, as you will prime your pump later at this
location. (
Fig. 3)
2. Install a 3/4 x 3/4 x 3/4 in. galvanized tee fitting.
(
Fig. 2)
4
This manual is related to the following products: