PUMP PRIMING & STARTUP

Shallow Well Application Only:

CAUTION: All pumps must be primed (filling the

cavity with water) before they are first operated. This

may take several gallons of water, as the suction line will

be filled in addition to the pump cavity.
1. Remove the 1/2 in. priming plug with pressure gauge

and air relief plug. (

Fig. 1)

IL1402

Priming plug

with pressure

gauge

Air relief plug

1

IL1403

2

IL1404

3

IL1405

4

4. Thread in priming plug and then open optional ball

valve if installed by turning handle to line up with the

pipe.

(Fig. 4)

5. Turn on breaker to start pump

IMPORTANT: If the pump hums instead

of pumping or turns off repeatedly, shut pump off

immediately.
Check voltage. Make sure your incoming voltage

matches the pump wiring voltage. See wiring guide in the

instructions.

3. Replace air relief plug and continue adding water to

pump cavity until water reaches the top of the priming

plug.

(Fig. 3)

2. Slowly fill pump cavity until water comes out of air

relief hole on top of the pump.

(

Fig. 2)