FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com

022354

Booster Pump Flow Protector

Operating Instructions & Parts Manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per-
sonal injury and/or property damage! Retain instructions for future reference.

FW1023

1106

Supersedes

NEW

General Safety Information

Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.

This is a SAFETY ALERT SYMBOL. When you
see this symbol on the pump or in the manual,
look for one of the following signal words and
be alert to the potential for personal injury or

property damage.

Warns of hazards that WILL cause serious

personal injury, death or major property damage if ignored.

!

Warns of hazards that CAN cause serious

personal injury or death, if ignored.

Warns of hazards that MAY cause minor

personal injury, product or property damage if ignored.

IMPORTANT: Indicates factors concerned with operation,
installation, assembly or maintenance which could result in
damage to the machine or equipment if ignored.
NOTE: Indicates special instructions which are important but
are not related to hazards.

Verify motor is wired for correct

voltage. See motor wiring diagram provided
by the pump or motor manufacturer.

Ground motor before connecting to

power supply.

Meet United States National Electrical

Code and local codes for all wiring.

Do not handle a pump, pump motor

or control unit with wet hands or when
standing on a wet or damp surface or in
water.

Hazardous
voltage. Can
shock, burn or
cause death.
Ground pump
before connecting
to power supply.

!

Follow wiring instructions in this manual when

connecting to power lines.

!

Always disconnect power source before

performing any work on or near the motor or its connected
load.

Control Box
115V SPECIFICATIONS
Enclosure . . . . . . . . . . . . . . . . . . . . NEMA 1 Indoor Use Only
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Maximum HP Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Hertz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50/60
Contact Rating . . . . . . . . . . . . . . . . . . . 15 Amps @ 115/Volts

Flow Sensor
Contact Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . .Max 20VA
Min. Flow for Contat Closure . . . . . . . . . . . . . . . . . . .1 GPM
Pressure Rating . . . . . . . . . . . . . . . . . . . . . . . . Max. 150 PSIG
Temperature Rating . . . . . . . . . . . . . . . . . . . . . . 32 to 140˚ F
Inlet and Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . 1” Slip PVC

Control Box
230V SPECIFICATIONS
Enclosure . . . . . . . . . . . . . . . . . . . . NEMA 1 Indoor Use Only
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Maximum HP Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Hertz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50/60
Contact Rating . . . . . . . . . . . . . . . . . . . 20 Amps @ 230/Volts

Flow Sensor
Contact Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . .Max 20VA
Min. Flow for Contat Closure . . . . . . . . . . . . . . . . . . .1 GPM
Pressure Rating . . . . . . . . . . . . . . . . . . . . . . . . Max. 150 PSIG
Temperature Rating . . . . . . . . . . . . . . . . . . . . . . 32 to 140˚ F
Inlet and Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . 1” Slip PVC