5

Ventilation

Ventilation and drainage must be provided to prevent

damage to the motor from heat and moisture.

Freezing

The pump and all piping must be protected from freezing.

If freezing weather is forecast, drain pump or remove

completely from the system.

Water Supply

The water source must be able to supply enough water to

satisfy the capacity of the pump and water needs.

Suction Lift

Suction lift is the vertical distance from the lowest level

of the water to the pump intake. See performance charts

on page 2 and 3 to determine how far your pump can lift

water.

Horizontal Distance

The horizontal distance is the horizontal measurement

between the pump suction and the water source. This

distance may affect the ability of the pump to operate. If it

is over 100 feet, call the manufacturer for assistance at

1-800-742-5044.

Pipe And Fittings

Use galvanized steel or NSF PW Schedule 40 PVC pipe

and fittings. This material is designed for water pressure

and will seal against air and water under pressure. Do Not

Use: DWV fittings, as these are designed for drains without

pressure and will not seal properly. (Fig. 1, 2 & 3)

CAUTION: The entire system must be air and water

tight for efficient operation and to maintain prime.

Wire Size:

The wire size is determined by the distance from the power

source to the pump motor, and the horsepower rating of the

motor. See the wire chart for proper wire size.

GENERAL PUMP INFORMATION

WIRE SIzE CHART CHART 2

Recommended Copper Wire and Fuse Sizes

HP Rating of Single Phase Motors

Distance

from Motor

to Meter

1/3

1/2

3/4

1

1-1/2

0-50’
115V
230V

14 GA
14 GA

12 GA
14 GA

12 GA
14 GA

10 GA
14 GA

10 GA
12 GA

50-100’
115V
230V

14 GA
14 GA

12 GA
14 GA

12 GA
14 GA

10 GA
14 GA

8 GA
12 GA

100-150’
115V
230V

14 GA
14 GA

12 GA
14 GA

10 GA
14 GA

10 GA
12 GA

6 GA
12 GA

150-200’
115V
230V

12 GA
14 GA

12 GA
14 GA

10 GA
12 GA

8 GA
12 GA

*
10 GA

200-300’
115V
230V

12 GA
14 GA

10 GA
14 GA

8 GA
12 GA

6 GA
10 GA

*
10 GA

Fuse Size
115V
230V

Amps
15
15

Amps
20
15

Amps
20
15

Amps
30
15

Amps
30
20

*Not economical to run in 115V. Use 230V.

6

IL0189

Pressure Switch

Discharge

Suction

Priming Port

Shallow Well Ejector

6. CPJ Shallow Well 1/3 - 1/2 HP (Fig. 6)