beautypg.com

Flint & Walling SPM User Manual

Owner's manual, Spm series lawn and turf pumps

background image

236222 0403

OWNER'S
MANUAL

WARNING - RISK OF ELECTRICAL SHOCK

Have an electrician provide electrical power to the motor.

Motor must be grounded and terminal cover in place to reduce
electrical shock hazard.

Keep motor operating area as dry as possible.

A ground fault interrupter (GFI) protected circuit is recom-
mended for use with any electrical device operating near water.

Always disconnect power before servicing.

Not investigated for use in swimming pool areas.

SAFETY WARNINGS

BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.

WARNING - ELECTRICAL PRECAUTIONS

All wiring, electrical connections, and system grounding must
comply with the National Electrical Code (NEC) and with any local
codes and ordinances. Employ a licensed electrician.

SAFETY

CAUTION

Review instructions before operating.

CAREFULLY READ THESE SAFETY

MESSAGES IN THIS MANUAL AND ON PUMP.

APPLICATION

This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft. In all

installations, friction losses in the suction pipe must be taken into
consideration.

PERFORMANCE

INSTALLATION

PUMP LOCATION: The pump should be installed in a clean, dry
and ventilated location which provides adequate drainage and
room for servicing and protection from freezing temperatures. It
should be bolted down evenly on a good foundation, preferably
concrete, to prevent the development of unnecessary stress.
Locating the pump as close as possible to the source of water
supply reduces the friction losses in the suction pipe and provides
for maximum capacities.

SUCTION PIPE: It is recommended that only new clean pipe or

hose be used and the size be the same as that of the pump
suction tapping. If the pump is installed any appreciable distance
away from the source of water supply, the suction pipe should be
increased by one size. The suction pipe must always slope
upwards from the water source to the pump to avoid air pockets
in the line. In cases where the pump has to be reprimed often and
it is not necessary that a lot of water be delivered, it is advisable
to use a 90° or 45° elbow on the suction line. This enables the
pump to prime sooner and also prevents kinking of the hose. In
cases where a maximum volume of water is required over a pro-

FW0501

SPM SERIES

Lawn and Turf Pumps

Electric Motor Driven

Flow in GPM

Flow in L/min.

PUMP

at total head (ft.)

at total head (Meters)

MODEL

HP

25

50

75

100

125 150

10

20

30

40

50

SPM30

3

110

92

71

40

371

276

110

SPM50

5

141

121

98

66

560

466

348

148