beautypg.com

Function, Interlocking module mgb-l0.b-pn, Locking modules mgb-l1.b-pn. and mgb-l2.b-pn – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual

Page 6: Function 6

background image

Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)

6

Function

Interlocking module MGB-L0.B-PN.

Together with a handle module, the interlocking module makes it possible to inter-

lock movable safety guards. The combination also serves as a mechanical door

stop at the same time.
The following switch-on condition applies to safety bit

SI1.0 ( see also System

status table and section PROFIsafe data bytes):

ÌSafety guard closed (T)
ÌBolt tongue inserted into interlocking module (R)

The interlocking module detects the position of the safety guard and the position

of the bolt tongue.
The bolt tongue in the handle module is moved into and out of the interlocking

module by actuating the door handle.

Locking modules MGB-L1.B-PN. and MGB-L2.B-PN.

Together with a handle module, the locking module makes it possible to lock

movable safety guards. The combination also serves as a mechanical door stop

at the same time.

Important!

To operate the device as a guard lock according to EN 1088, the signals for
door position (T=PROFIsafe bit

SI0.2), bolt position (R= PPOFIsafe bit SI0.3)

and guard lock monitoring (Z= PROFIsafe bit

SI0.4) must be polled in a logical

AND operator. This operator is already implemented in the PROFIsafe data block
(safety bit

SI1.0).

As an alternative, you can also link the bits

SI0.2 to SI0.4 individually to your

control system.

The following switch-on condition applies to safety bit

SI1.1 ( see also System

status table and section PROFIsafe data bytes):

ÌSafety guard closed (T)
ÌBolt tongue inserted into locking module (R)
ÌLocking arm in locking position (guard lock monitoring) (Z)

The locking module detects the position of the safety guard and the position of

the bolt tongue. The position of the locking arm is also monitored.
The bolt tongue in the handle module is moved into and out of the locking module

by actuating the door handle.
When the bolt tongue is fully inserted in the locking module, the locking arm locks

the bolt tongue in this position. Depending on the version, this locking is by spring

force or solenoid force.