beautypg.com

Data block for diagnostic function – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual

Page 33

background image

Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)

33

Data block for diagnostic function

Function

Slot

Required memory in data range of the control system (IO controller)

(see below for exact bit allocation)

Diagnostics

For slot assignment, see data

sheet

Input range

(1 byte)

Message

Life

-

-

272(6)

273(6)

272(2)

273(2)

272(1)

273(1)

274(4)

72

Bit

I0.7

I0.6

I0.5

I0.4

I0.3

I0.2

I0.1

I0.0

Output range

(1 byte)

Acknowledg-

ment

-

-

-

-

-

-

Reset

MGB

Ac-

knowl-

edg-

ment

Bit

O0.7

O0.6

O0.5

O0.4

O0.3

O0.2

O0.1

O0.0

Bit allocation

Input range

Bit

Description

Output range

Bit

Description

I0.0

Device diagnosis (PROFIsafe error 72): message present. Diag-

nostic code: see table of device-specific messages.

O0.0

Device diagnosis: Acknowledge message; acknowledgment of

I0.2, I0.3 or I0.4. I0.0 is also acknowledged if only one

message is present

I0.1

Device diagnosis, device-specific message 274(4) "Plausibility

check found an error (e.g. escape release actuated)"

O0.1

Trigger MGB locking module reset: Acknowledge message;

acknowledgment of

I1. I0 is also acknowledged if only one

message is present.

I0.2

Device diagnosis, device-specific message 272(1) or 273(1)

"Error in emergency stop"

O0.2

n.c.

I0.3

Device diagnosis, device-specific message 272(2) or 273(2)

"Error in enabling switch"

O0.3

n.c.

I0.4

Device diagnosis, device-specific message 272(6) or 273(6)

"Error in operating mode selector switch"

O0.4

n.c.

I0.5

n.c.

O0.5

n.c.

I0.6

n.c.

O0.6

n.c.

I0.7

Mechanical life > 1 million operating cycles

O0.7

n.c.