Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)

10

Case C

You have an MGB with a version number of V 2.36.4 and a GSD file with a version

number from ..._110026-20110815.
The guard locking solenoid is controlled if:

Ìbit SO 0.0 = 1 (factory setting)

Truth table:

PROFINET bit

PROFIsafe bit

Guard locking with

O 0.0

not relevant

SO 0.0

MGB-L1...

MGB-L2...

0

0

active

inactive

0

1

inactive

active

1

0

active

inactive

1

1

inactive

active

What must be observed?
You can define in the GSD file whether bit O 0.0 may be used for control in addition

to bit SO 0.0. The setting is specified in the parameter Locking module – solenoid

control.
If O 0.0 is additionally used, the guard locking solenoid is controlled if
for MGB-L1...

Ìbit SO 0.0 AND bit O 0.0 = 1
Ìfor MGB-L2... bit SO 0.0 OR bit O 0.0 = 1

Truth table:

PROFINET bit

PROFIsafe bit

Guard locking with

O 0.0

SO 0.0

MGB-L1...

MGB-L2...

0

0

active

inactive

0

1

active

active

1

0

active

active

1

1

inactive

active