Data blocks of individual functions at a glance, Data block for emergency stop function (optional) – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual
Page 31

Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)
31
Data blocks of individual functions at a glance
Function data blocks are required for all additional functions that are not included
in the data blocks for MGB modules.
Data block for signal stack module function (optional)
If your MGB system includes this function, the interface to the signal stack module
is usually plug connector X6. The following table shows which bit is assigned to
which pin of X6. Please refer to the data sheet for any deviations from this.
Function
Slot
Required memory in data range of the control system (IO controller)
(Refer to the data sheet of your device for the exact bit allocation)
Signal stack module
For slot assignment,
see data sheet
Output range
(1 byte)
Pin
-
-
-
X6.8
X6.6
X6.5
X6.2
X6.7
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Output range
Bit
Description
O0.0
Pin 7 on plug connector X6
O0.1
Pin 2 on plug connector X6
O0.2
Pin 5 on plug connector X6
O0.3
Pin 6 on plug connector X6
O0.4
Pin 8 on plug connector X6
O0.5
n.c.
O0.6
n.c.
O0.7
n.c.
Data block for emergency stop function (optional)
Function
Slot
Required memory in data range of the control system (IO controller)
(Refer to the data sheet of your device for the exact bit allocation)
Emergency stop
For slot assignment, see data
sheet
Input range
(1 byte)
Switching ele-
ment
-
-
-
-
-
-
-
Signal-
ing
contact
Bit
I0.7
I0.6
I0.5
I0.4
I0.3
I0.2
I0.1
I0.0
Output range
(1 byte)
Display
-
-
-
-
-
-
-
LED
(op-
tional)
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Input range
Bit
Description
Output range
Bit
Description
I0.0
Emergency stop signaling contact
O0.0
Emergency stop lighting (optional)
I0.1
n.c.
O0.1
n.c.
I0.2
n.c.
O0.2
n.c.
I0.3
n.c.
O0.3
n.c.
I0.4
n.c.
O0.4
n.c.
I0.5
n.c.
O0.5
n.c.
I0.6
n.c.
O0.6
n.c.
I0.7
n.c.
O0.7
n.c.