Data block for enabling switch function (optional) – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual
Page 32
Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)
32
Data block for enabling switch function (optional)
Function
Slot
Required memory in data range of the control system (IO controller)
(Refer to the data sheet of your device for the exact bit allocation)
Enabling switches
V
4
2
C
D
1
X
2
C
D
2
X
X14
For slot assignment, see data
sheet
Input range
(1 byte)
Function
Holder
+ but-
ton
- button
-
-
-
-
Enabling
Bit
I0.7
I0.6
I0.5
I0.4
I0.3
I0.2
I0.1
I0.0
Output range
(1 byte)
Display
-
-
-
-
-
-
- button
LED
+
button
LED
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Input range
Bit
Description
Output range
Bit
Description
I0.0
Enabling switch in "enabling" position (signaling contact)
O0.0
Enabling switch illumination for + button
I0.1
n.c.
O0.1
Enabling switch illumination for - button
I0.2
n.c.
O0.2
n.c.
I0.3
n.c.
O0.3
n.c.
I0.4
n.c.
O0.4
n.c.
I0.5
Enabling switch + button
O0.5
n.c.
I0.6
Enabling switch – button
O0.6
n.c.
I0.7
Enabling switch stop detection
O0.7
n.c.
Data block for operating mode selector switch function (optional)
Function
Slot
Required memory in data range of the control system (IO controller)
(Refer to the data sheet of your device for the exact bit allocation)
Operating mode selector
switch
For slot assignment, see
data sheet
Input range
(1 byte)
Switch (coding 2
from 3)
-
-
-
-
-
S91
Bit
I0.7
I0.6
I0.5
I0.4
I0.3
I0.2
I0.1
I0.0
Output range
(1 byte)
Display
-
-
-
-
-
-
-
-
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Input range
Bit
Description
Output range
Bit
Description
I0.0
Operating mode selector switch bit 1
O0.0
n.c.
I0.1
Operating mode selector switch bit 2
O0.1
n.c.
I0.2
Operating mode selector switch bit 3
O0.2
n.c.
I0.3
n.c.
O0.3
n.c.
I0.4
n.c.
O0.4
n.c.
I0.5
n.c.
O0.5
n.c.
I0.6
n.c.
O0.6
n.c.
I0.7
n.c.
O0.7
n.c.