Profinet alarms, Fault in stacklight module – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual
Page 37

Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)
37
PROFIsafe errors
No.
Description
Measures/remedying errors
276(1)
Starting error PROFIsafe
Please contact our support
organization!
276(2)
Memory error RAM
276(3)
Memory error FLASH
276(4)
Communication error
276(5)
Synchronization error
276(6)
Voltage monitoring
General messages of the overall system
No.
Description
Measures/remedying errors
277(1)
Starting error MGB
Please contact our support
organization!
277(2)
Communication error
278
Internal device error
Cyclical Profisafe status message
Bit
Description
Measures/remedying errors
0
reserved
-
1
Error in F-Device or F-Module
Subscriber is passivated (on
LED flashes).
You will find information on
depassivating in the manual for
your control system.
2
Communication error, CRC error
3
Communication error, watchdog
timeout
4
Fail-safe values activated
-
5
Toggle bit
-
6
Consecutive number was reset
-
7
reserved
-
PROFINET alarms
Fault in stacklight module
Short circuits on the stacklight module are output as a PROFINET diagnostic alarm
(alarm number 1: short circuit).