Profinet alarms, Fault in stacklight module – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual

Page 37

background image

Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)

37

PROFIsafe errors

No.

Description

Measures/remedying errors

276(1)

Starting error PROFIsafe

Please contact our support

organization!

276(2)

Memory error RAM

276(3)

Memory error FLASH

276(4)

Communication error

276(5)

Synchronization error

276(6)

Voltage monitoring

General messages of the overall system

No.

Description

Measures/remedying errors

277(1)

Starting error MGB

Please contact our support

organization!

277(2)

Communication error

278

Internal device error

Cyclical Profisafe status message

Bit

Description

Measures/remedying errors

0

reserved

-

1

Error in F-Device or F-Module

Subscriber is passivated (on

LED flashes).

You will find information on

depassivating in the manual for

your control system.

2

Communication error, CRC error

3

Communication error, watchdog

timeout

4

Fail-safe values activated

-

5

Toggle bit

-

6

Consecutive number was reset

-

7

reserved

-

PROFINET alarms

Fault in stacklight module

Short circuits on the stacklight module are output as a PROFINET diagnostic alarm

(alarm number 1: short circuit).