Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)

15

Lockout mechanism

If the lockout mechanism is pivoted out, the bolt tongue cannot be extended. The

lockout mechanism can be secured with padlocks (see Figure 7).
To pivot out, press the grooved part (only possible with bolt tongue retracted).

Figure 7: Lockout mechanism secured with padlock

Escape release (optional)

The escape release is used to open a locked safety guard from the inside without

tools.

Warning!

Loss of the safety function due to incorrect mounting of the escape release.

ÌThe actuation axis for the escape release must be inserted min. 10 mm into

the handle module.

ÌFor profile widths larger than 40 mm and when using mounting plates, use a

250-mm actuation axis (order No. 106 761) and cut it to size.

ÌIn case of profile widths smaller than 40 mm, cut actuation axis and protective

sleeve to length.

ÌAlign escape release axis at right angles to the handle module. See figure on

left and Figure 8.

ÌFit escape release such that operation, inspection and maintenance are pos-

sible.

Important!

The system enters into a latching fault when the escape release is actuated.
See “System status table LEDs on interlocking/locking module” on page 38,
state Signal sequence erroneous (DIA1 flashes 7 times).

Note:

The system might not enter into a latching fault if the escape release is actuated

very slowly.

1

Order no.. 100464 (right)

Order no.. 106619 (left)

Order no.. 111157 (right)

Order no.. 111158 (left)

2

Key:
1

Padlock ∅ min. 2 mm, ∅ max.

10 mm

Note:

You can fit a maximum of 3 locks

Ø 8 mm..

2

Automatically extending, second

lockout mechanism

Padlock

min. 6 mm, ∅ max.

10 mm