Controls and indicators – EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual
Page 21
Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)
21
Controls and indicators
Data
Link
SF
BF
ON
B
U
1
1
2
Link
Data
2
X1
X3
X4
PN1
PN2
X2
DC24V DC24V
Data2
Link2
SF
BF
ON
UB
Link1
State
DIA2
Power
DIA1
Data1
3
6
1
2
5
1
2
3
4
4
LEDs on the bus module
LED
Color
Description
Link 1 and
Link 2
green
Bus plug inserted:
statically on
Data 1 and
Data 2
yellow
Data transfer:
flashing
SF
red
System error:
statically on
(see section on diag-
nostic messages of
the MGB system)
BF
red
Bus error:
statically on
(see section on diag-
nostic messages of
the MGB system)
ON
green
Self test OK:
statically on
Subscriber passiv-
ated: flashing
UB
green
Power supply OK:
statically on
LEDs on evaluation module
see System status table
DIPswitches for PROFIsafe address
For coding see above
Figure 16: Displays and controls/binary coding of the DIPswitches for PRO-
FIsafe address (factory setting: 135)
3
6
1
2
5
1 2 3 4
4
1 2 4 8 16 32
64
128
256
512
OFF
ON
ON
OFF
default address:
128 + 4 + 2 + 1 = 135
Binary coding of the
DIPswitches for PRO-
FIsafe address (factory
setting: 135)
Cover for DIPswitches