EUCHNER MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B User Manual
Page 19
Operating Instructions Safety System MGB-L..B-PN.-... (PROFINET)
19
Changing the actuating direction (here: from right to left)
Important!
It is only possible to make this change when the bolt tongue is not extended and
an escape release is not yet mounted.
As supplied, the handle module is set either for doors hinged on the right or for
doors hinged on the left.
Based on the example of a handle module for doors hinged on the right this means:
ÌThe safety guard opens by pressing down the door handle.
ÌThe system is mounted the other way up for doors hinged on the left. In other
words, the safety guard opens by pressing up the door handle (see Figure 10).
For this reason the actuating direction of the door handle must be changed
(see Figures 10 - 15).
(This is similar for handle modules for doors hinged on the left.)
CLOSED
OPEN
1
3
2
1
Press door handle up.
2
Unscrew locking pins.
3
Push cover aside.
Figure 10: Changing actuating direction, step 1
Figure 11: Changing actuating direction, steps 2 and 3
4
5
4
Lift the locking pin on the door handle using a screwdriver
and hold it in this position.
5
Turn door handle to the right.
7
6
b
8
a
4 mm
6
Only if using an escape release: using the hexagon head
screw, turn the joint counterclockwise from position (a) to
position (b).
7
Close cover.
8
Screw in locking pins and tighten to 2 Nm.
Figure 12: Changing actuating direction, steps 4 and 5
Figure 13: Changing actuating direction, steps 6 to 8