beautypg.com

Maintenance, Vent plug, Pressure and flow settings a caution – Enerpac PL-Series User Manual

Page 6: Push/pull forces vs. system pressure, Figure 3 6

background image

Vent Plug

Single-acting cylinders have a vented plug on the left side of the cylinder when you are
facing the hydraulic ports. To prevent entry of chips and coolant, the vent plug must not
be removed. If the vent plug is subjected to a continuous coolant flood condition, attach
tubing to the port using a BSPP fitting and run the tubing to a non-contaminated area of
the fixture.

Pressure and Flow Settings

A

CAUTION

It is very important that you use the correct pressure and flow settings.
Operating outside these limits will cause damage to the cylinder. Damage
caused by exceeding rated pressure and maximum flow is NOT COVERED BY
WARRANTY.

Push/Pull Forces vs. System Pressure

NOTE: Push forces are for double-acting cylinders only.

MAINTENANCE

Maintenance is required when wear or leakage is noticed. Occasionally inspect all
components to detect any problem requiring service and maintenance. Enerpac offers
ready-to-use Repair Parts Kits. Repair Parts Sheets are available with assembly drawing
and parts list. Contact Enerpac.

IMPORTANT: Consult the Repair Parts Sheet for service information as to correct
assembling and disassembling. Incorrect maintenance and service such as wrong torque
values may cause product malfunctions and/or personal injury.

Pull Force:

Push Force:

Force kN [lbs.]

2,2 kN [500 lbs.]

275,8

Pressure bar [psi]

[300]

137,9

68,9

0,4

0

[100]

1,3

[1000]

206,8

[3000]

[2000]

[4000]

4,0

3,1

[500]

2,2

[700]

[1100]

[900]

4,9

1,54 X pressure

344,7

[5000]

Stroke

0,75 x pressure

Push

Pull

[2200]

9,8

8,0

[1800]

[1400]

6,2

4,5

[1000]

[600]

2,7

[200]

0,9

Force kN [lbs.]

5,6 kN [1250 lbs.]

344,7
[5000]

Pressure bar [psi]

137,9

68,9

[1000]

0

[2000]

206,8

275,8

[3000]

[4000]

Push Force:

Pull

Push

Pull Force:

Stroke

[2600]

11,6

[3000]

13,3

1,79 x pressure

3,80 x pressure

[6000]

26,7

22,2

[5000]

[4000]

17,8

13,3

[3000]

[2000]

8,9

[1000]

4,4

Force kN [lbs.]

9,0 kN [2000 lbs.]

344,7

[5000]

Pressure bar [psi]

137,9

68,9

[1000]

0

[2000]

206,8

275,8

[3000]

[4000]

3,13 x pressure

8,04 x pressure

Push Force:

Pull

Push

Pull Force:

Stroke

Push

Pull

[2000]

137,9

Pressure bar [psi]

20,0

6,7

[4500]

[1500]

68,9

[1000]

0

86,7

73,4

60,0

46,7

33,3

[19500]

[16500]

[13500]

[10500]

[7500]

Force kN [lbs.]

Push Force: 23,76 x pressure

[5000]

344,7

206,8

275,8

[3000]

[4000]

Pull Force: 12,42 x pressure

Stroke

35,0 kN [7900 lbs.]

Figure 3

6

This manual is related to the following products: