beautypg.com

Mounting specifications – Enerpac PL-Series User Manual

Page 3

background image

MOUNTING SPECIFICATIONS

Mounting Threaded Body Cylinders

Threaded body cylinders can be threaded into a tapped hole, secured to the fixture using
a mounting flange, threaded into the fixture and secured with a jam nut, or mounted
through a clearance hole and secured with jam nuts. See illustrations below.

When a threaded body pull cylinder is being installed in a fixture, the thread engagement
should be no less than the thread engagement for the standard Enerpac mounting flange.
If a cylinder is being mounted using just the lower portion of the threads, the engagement
should be increased for additional support. See table below for minimum thread
engagement.

Cylinder Capacity

Minimum Thread Engagement

2,2 kN

500 lb

13 mm

.50"

5,6 kN

1250 lb

13 mm

.50"

9 kN

2000 lb

16 mm

.63"

35 kN

7900 lb

30 mm

1.25"

oil connection

jam nut

threaded into fixture

mounting flange

oil connection

jam nuts

Figure 1