Sequence of operation for inert atmosphere oven – Despatch LCC/LCD2-14-3 Non Pass Through Series User Manual
Page 33
24
5.
Run the desired profile from the Protocol Plus controller.
Press the Select key until Profile is displayed (you can press the Run key at
any time to activate Profile Mode).
Press the
key to display the desired profile to run.
To start Profile Mode, press the Run key.
NOTE: The display will change from Stop to Run and the segment time
remaining, along with the current segment number, will be displayed.
6.
The oven profile cycle is in process and the door is LOCKED. The green beacon
light is on steady, the amber beacon light is off.
7.
When the process is complete, the amber beacon is on, and the door is
unlocked.
8.
The operator removes the product, and closes oven door to complete the
process cycle. The oven is ready for the next lot.
Sequence of Operation for Inert Atmosphere Oven
1.
After the system is powered up (see previous procedure), the Protocol Plus
controller is initialized to run an event. Refer to the Protocol Plus instructions in
this manual for more information on programming event outputs.
2.
At this point the oven is idle, empty, door closed, and waiting for the next lot to be
processed. The Protocol Plus is not running a profile.
3.
Open the oven door.
4.
Place the product on the shelf in the oven. Close the oven door.
5.
Run the desired profile from the Protocol plus controller.
Press the Select key until Profile is displayed (note that you can press
the Run key at any time to activate Profile Mode).
Press the
key to display the desired profile to run.
To start Profile Mode, press the Run key.