beautypg.com

Physical specifications, Functional specifications – Despatch LCC/LCD2-14-3 Non Pass Through Series User Manual

Page 13

background image

4

Physical Specifications

CHAMBER SIZE INCHES (CM)

CAPACITY
IN CU. FT.
(LITERS)

OVERALL SIZE INCHES (CM)

SHELVES
PROVIDED
ON SHELF
CENTERS

APPROX. WEIGHT

MAX. # OF
SHELVES

MODEL

WIDTH**

DEPTH

HEIGHT

WIDTH

DEPTH

HEIGHT

LBS.
(KG)
NET

LBS. (KG)
SHIPPING

LCC/LCD2-14

25.5 (64)

26 (66)

37 (94)

14 (396)

47.5
(121)

41.5
(105)

71 (180)

2 ON 3”

955
(434)

1050 (477)

11

LCC/LCD2-14V

LCC/LCD2-14N

25.5 (64)

26 (66)

37 (94)

14 (396)

47.5
(121)

41.5
(105)

71 (180)

2 ON 3”

955
(434)

1050 (477)

11

LCC/LCD2-14NV

LCC/LCD2-14A

25.5 (64)

26 (66)

37 (94)

14 (396)

47.5
(121)

41.5
(105)

71 (180)

2 ON 3”

955
(434)

1050 (477)

11

LCC/LCD2-14AV


V = Silicone free
N = Nitrogen
A = Class A
** Actual Clear width is 24.0” (61 cm)


Functional Specifications

ATMO-

SPHERE

TIME TO TEMP

(minutes, w/ no load)

COOLING TIME TO TEMP

(minutes, w/ no load)

TEMPERATURE

UNIFORMITY AT

CONTROL

STABILITY

OPERATING

RANGE

W / 20°C

AMBIENT

MAX LOAD

CAPACITY

LBS. (KG)

MAX

SHELF

CAPACITY

LBS. (KG)

RECIRCULATING

FAN

MODEL

50-

100°C

50-

175°C

50-

260°C

50-

350°C

100-

65°C

175-

65°C

260-

65°C

350-

65°C

100°C 175°C 260°C 350°C

CFM

H.P.

LCC/LCD
2-14

AIR

3

9

15

35*

41

82

95

116* ±1°C ±2°C ±3°C ±3.5°C

±0.5°C

60-260°C*

400

50

950

1.5

LCC/LCD
2-14V

LCC/LCD
2-14N

INERT

3

9

15

35*

20

25

30

35*

±1°C ±2°C ±3°C ±3.5°C

±0.5°C

30-260°C*

400

50

950

1.5

LCC/LCD
2-14NV

LCC/LCD
2-14A

AIR

3

9

15

35*

41

82

95

116* ±1°C ±2°C ±3°C ±3.5°C

±0.5°C

60-260°C*

400

50

950

1.5

LCC/LCD
2-14AV


V = Silicone free
N = Nitrogen
A = Class A

Notes: Figures based on actual tests in an empty oven: uniformity can vary slightly depending on unit and operating conditions.
Specifications are subject to change without notice.
Addition of water cooling to air units provides cooling time to temperature equivalent to the inert units. Assumes 55°F (13ºC)
maximum water temperature at 3 GPM (11 LPM).
Exhaust fan specification is 85 CFM.
380V, and other special voltages not included.

*LCD operating range is 60º-350ºC. All measurements to and from 350ºC are based on LCD models