6 multi-point tcp pair connections, Multi-point tcp pair connections, Sec. 3.5.6 – Atop Technology SE5002D User manual User Manual
Page 54: Fig. 3. 31
![background image](/manuals/554962/54/background.png)
Atop Serial Device Server
SE5002D
User Manual V. 1.1
3.5.6 Multi-Point TCP Pair Connections
The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection
is that the TCP implementation would also exchange flow controls pins of RS-232. However,
the TCP Server is limited to a maximum of four connections. If there are than four serial
devices and does not use flow control pins of RS-232, it is possible to setup pair connection in
UDP mode,
. After multi-connection is enabled in the WebUI, refer to the following
table to setup Pair Connection as in
Table 3. 2
IP Address
Link Mode
Local Listening Port
Destination IP
Destination Port
SE5002D Master COM1
10.0.50.100
TCP Server
5000
-
-
SE5002D Slave 1 COM1
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 1 COM2
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM1
10.0.50.201
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM2
10.0.50.201
TCP Client
-
10.0.50.100
5000
Fig. 3. 31