4.3 Configure by Hyper Terminal console utility
1. Power off GW51C-MAXI Serial Server.
2. Set the MODE switch SW1 to ‘OFF’ and SW2 to ‘ON’.
3. Use a PC to connect to GW51C-MAXI Serial Server’s console with RS-232 cross over cable.
4. Power on GW51C-MAXI Serial Server.
5. Open a Hyper Terminal program from ones computer Start menu -> Programs -> Accessories ->
Communication -> Hyper Terminal, set COM2 parameters as follows.
-
Baud rate: 9600 bps
-
Data bit: 8 bits
-
Parity: None
-
Stop bit: 1bit
-
Flow control: None
Note:
At present time baud rate is fixed at 9600, 8, n, 1, without flow control for console port
communication, RS-232C parameters of ones computer COM port and GW51C-MAXI Serial Server
must be the same.