4.3 Configure by Hyper Terminal console utility

1. Power off GW51C-MAXI Serial Server.

2. Set the MODE switch SW1 to ‘OFF’ and SW2 to ‘ON’.

3. Use a PC to connect to GW51C-MAXI Serial Server’s console with RS-232 cross over cable.

4. Power on GW51C-MAXI Serial Server.

5. Open a Hyper Terminal program from ones computer Start menu -> Programs -> Accessories ->

Communication -> Hyper Terminal, set COM2 parameters as follows.

-

Baud rate: 9600 bps

-

Data bit: 8 bits

-

Parity: None

-

Stop bit: 1bit

-

Flow control: None

Note:

At present time baud rate is fixed at 9600, 8, n, 1, without flow control for console port
communication, RS-232C parameters of ones computer COM port and GW51C-MAXI Serial Server
must be the same.