SECTION 6 - JLG CONTROL SYSTEM
6-102
– JLG Lift –
3121171
MAIN BOOM (ABV or BLW) ELE
Displays the main boom status being above or below of the elevated case
MAIN TRN LENC (CL or OP)
Displays the status of the normally open length switch
MAIN TRN LENO (CL or OP)
Displays the status of the normally closed length switch
MAIN TRN LEN (A/D or B/C or DISAGREE)
Displays the status of the combined length switches
DUAL CAP LENC (CL or OP)
Displays the status of the normally open dual capacity switch
DUAL CAP LENO (CL or OP)
Displays the status of the normally closed dual capacity switch
DUAL CAP LEN (A or A/B or B or B/C or C/D
or D or FLT)
Displays the status of the combined dual capacity switches
TWR TRN SW C (CL or OP)
Displays the status of the normally open tower transport switch
TWR TRN SW O (CL or OP)
Displays the status of the normally closed tower transport switch
TWR TRN SW (CL or OP or FLT)
Displays the status of the combined tower transport switches
TWR TR ANG SW (CL or OP)
Displays the status of the tower angle switch
MAIN TRN AGLC (CL or OP)
Displays the status of the normally open main angle switch
MAIN TRN AGLO (CL or OP)
Displays the status of the normally closed main angle switch
MAIN TRN AGL (CL or OP or FLT)
Displays the status of the combined main angle switches
LOAD PIN:
MOMENT (XXXXXXX)
Displays the calculated value of the moment pin
RATIO (XX.XXX)
Displays the calculated value of the lift cylinder vector force ratio
ANGLE (XX.X)
Displays the calculated angle of the vector force
V.F. (X)
Displays the vector force applied to the moment pin
RAW MOMENT (XXXXXXX)
Displays the raw data value of the moment pin
RAW RATIO (XX.XXX)
Displays the raw value of the lift cylinder vector force ratio
RAW ANGLE (XX.X)
Displays the raw angle of the vector force
RAW V.F. (X)
Displays the raw data vector force applied to the moment pin
CAL PT ANGLE (XX.X)
Displays the angle of the vector force applied to the moment pin during
calibration
CAL PT VECTOR (X)
Displays the vector force applied to the moment pin during calibration
CAL PT MOMENT (XXXXXXX)
Displays the value of the moment pin recorded during calibration
E FLAGS (#X####)
Displays error flags from the moment pin
X (XXX)
Displays the calculated horizontal force applied to the moment pin
Y (XXX)
Displays the calculated vertical force applied to the moment pin
RAW X (XXX)
Displays the horizontal force applied to the moment pin
RAW Y (XXX)
Displays the calculated vertical force applied to the moment pin
Table 6-7. Analyzer Diagnostics Menu
Menu:
Submenu:
Selection:
Description: