Table 6-7. Analyzer Diagnostics Menu
Menu:
Submenu:
Selection:
Description:
DIAGNOSTICS:
SYSTEM:
GM BATTERY (XX.XX) V
Displays battery voltage at ground module
PM BATTERY (XX.XX) V
Displays battery voltage at platform module
AMB. TEMP (XX) C
Displays ambient temperature
PLATFORM SW (CL or OP)
Displays the OPEN or CLOSED condition of the ground switch
GROUND SW (CL or OP)
Displays the OPEN or CLOSED condition of the platform switch
MODE (GROUND or PLAT)
Displays the current operation mode of the machine
ABOVE ELEV. (YES or NO)
Displays the current condition of the ABOVE ELEVATION case
LEN SW 1 (CL or OP)
Displays the current condition of length switch #1
LEN SW 2 (CL or OP)
Displays the current condition of length switch #2
RETRACTED (YES or NO)
Displays the status of the RETRACTED case
TRANSPORT (YES or NO)
Displays the status of the TRANSPORT case
BR CABLE CUT (OP or CL)
Displays the status of the BROKEN CABLE case
BCS (NORMAL or XXXX VIOL)
Displays the status of the Boom Control System
MN ENV (NOMINAL or (STOP or
VIOL)(TOP or BOT))
Displays the main boom envelope status
TW ENV (NOMINAL or (STOP or
VIOL)(FWD or BACK))
Displays the tower envelope status
(HR or ER)(GRAV or PWR)(DOWN or
DN)(SS or NP)(ML or TT)
Displays the current retrieval mode and conditions
LENGTH ZONE (A or B or C or d or ERR)
Displays the status of the main boom length zone
ANGLE ZONE (1 or 2 or 3 or 4 or 5 or 6 or 7 or
8 or HI)
Displays the status of the main boom angle zone
CREEP (NOT ACTIVE or ACTIVE)
Displays creep switch status
CRP MODE (NOT ACT or ACTIVE)
Displays the current condition of creep mode
SUPER CREEP (OFF or ON)
Displays the current condition of super creep mode
TILT (XX.XX) DEG
Displays the measured vehicle combined tilt
TILT X (X.X)
Displays the measured vehicle tilt of the X axis
TILT Y (X.X)
Displays the measured vehicle tilt of the Y axis
AUX POWER (CL or OP)
Displays the status of auxiliary power switch
HORN (CL or OP)
Displays status of horn switch
BASKET STOWED (YES or NO)
Displays the status of the BASKET STOWED switch
SOFT LIMIT (CL or OP)
Displays the OPEN or CLOSED condition of the soft touch limit switch