JLG G6-42A Service Manual User Manual
Page 186
![background image](/manuals/551869/186/background.png)
Electrical System
9-30
G6-42A, G9-43A, G10-43A
b. Tilt/Auxiliary Calibration Menu
MENU
SUB-MENU
COMMENT
Calibrations:
Fork Tilt
Cal. Fork Tilt?
Yes: Enter, No: ESC
The technician will press the ENTER key to initiate calibration, or the
ESC key to leave menu.
Fork Tilt Roller
FWD to Max
The technician will knurl the fork tilt roller to the +AR position and
press the ENTER key to confirm.
Fork Tilt Roller
Center
The the technician will release the fork tilt roller and press the ENTER
key to confirm.
Fork Tilt Roller
REV to Max
The technician will knurl the fork tilt roller to the - AR position and
press the ENTER key to confirm.
Fork Tilt Roller
Center
The the technician will release the fork tilt roller and press the ENTER
key to confirm.
Calibrations:
Complete
The control system will display this message to advise that the
procedure was successful. The technician will press the ESC key to
leave this menu.
Calibrations:
Failed
The control system will display this message to advise that the
procedure was unsuccessful. The technician will press the ESC key to
leave this menu.
Calibrations:
Aux Hydraulic
Cal. Aux Hyd?
Yes: Enter, No: ESC
The technician will press the ENTER key to initiate calibration, or the
ESC key to leave menu.
Aux Hyd Roller
FWD to Max
The technician will knurl the auxiliary hydraulic roller to the +AR
position and press the ENTER key to confirm.
Aux Hyd Roller
Center
The the technician will release the auxiliary hydraulic roller and press
the ENTER key to confirm.
Aux Hyd Roller
REV to Max
The technician will knurl the auxiliary hydraulic roller to the - AR
position and press the ENTER key to confirm.
Aux Hyd Roller
Center
The the technician will release the auxiliary hydraulic roller and press
the ENTER key to confirm.
Calibrations:
Complete
The control system will display this message to advise that the
procedure was successful. The technician will press the ESC key to
leave this menu.
Calibrations:
Failed
The control system will display this message to advise that the
procedure was unsuccessful. The technician will press the ESC key to
leave this menu.