Driving 8-6, Steering 8-6, Electrical (gfci) outlets at platform 8-6 – Snorkel AB46J User Manual
Page 56: Securing for day 8-6, Blue and yellow, 8-6, Drive/steer controller, 8-6, 10-2, Platform control box, 8-6, Driving, 8-6, Electrical (gfci) outlets at platform, 8-6, Sudden stops, 8-6

■ Driving
Death or Serious Injury can result from
sudden stops. To avoid sudden stops, do not
remove your foot from the platform foot switch
while the AB46J is in motion.
The AB46J chassis can only be driven from the
platform control box. You cannot drive from the
ground control box.
There is a blue arrow on the forward end of the
chassis and a yellow arrow on the reverse end of
the chassis.
Pushing the Drive/Steer controller to FORWARD
causes the chassis to move in the direction of the
blue arrow on the end of the chassis.
Pushing the Drive/Steer controller to REVERSE
causes the chassis to move in the direction of the
yellow arrow on the opposite end of the chassis.
You must be stepping on the platform foot
switch for the Drive/Steer controller to work.
■ Steering
The AB46J can only be steered from the platform
control box. You cannot steer the AB46J from the
ground control box.
There are two blue arrows on the left side of the
chassis and two yellow arrows on the right side of
the chassis.
Pushing the Drive/Steer controller to LEFT
causes the front wheels to turn for a left turn.
Pushing the Drive/Steer controller to RIGHT
causes the front wheels to turn for a right turn.
You must be stepping on the platform foot
switch for the Drive/Steer controller to work.
When you release the Drive/Steer controller the
wheels stay where you set them. The wheels do
not return to the "straight ahead" position the way
automobile wheels do.
■ Electrical (GFCI) Outlets at Platform
If the 15 A circuit breaker on the GFCI outlet
trips, disconnect whatever is plugged into the
outlet, wait one minute, then press the circuit
breaker button back in. If the circuit breaker trips
a second time, refer the problem to a qualified
service technician.
The power input connector (3) for the electrical
box (1) is on the top rear of the chassis. Plug a
source of power into the power input connector
(3) if you intend to use the electrical box (1) to
power equipment. Unplug power source before
you move the AB46J.
■ Securing for Day
At the end of each work day the AB46J should be
returned to the STOWED POSITION and locked
as described under “Stowing” in the "Stowing and
Transporting" chapter 10.
page 8 - 6
AB46J – 0163187
8. Operation
DANGER