beautypg.com

Platform control box controls 6-5, Electronic display 6-5, Information messages 6-5 – Snorkel AB46J User Manual

Page 33: Wait messages 6-5, Operator action messages 6-5, Service required messages 6-5, Control switch location, 6-5, Information messages, 6-5, Oprator action messages, 6-5, Service required messages, 6-5

background image

Platform Control Box Controls

Electronic Display

The Electronic Display automatically turns on
when the AB46J is set for platform control box
operation. The Emergency Stop switch (1)
MUST be ON (pulled up), to provide power to the
Electronic Display to show a message.

The display can show four different types of
messages about the status of the drive system
and two service status messages:

1. Information messages

2. Wait messages

3. Operator Action messages

4. Service Required messages.

5. Set Up Data.

6. Fault Service Messages Stored In Memory.

To save the batteries, the Electronic Display
automatically turns itself off after 15 minutes if
the AB46J is not operated. To turn the display
back on, step on the foot switch or press the
Ground Operation switch.

Information messages

Report normal operating conditions for the AB46J
drive system. Anytime the AB46J is operated
correctly and is controlled from the

platform-control box an Information message will

appear in the electronic display.

Wait messages

Appear when certain components have
overheated. The AB46J cannot be driven while a
Wait message is being displayed. When the
message goes out the AB46J can be driven, until
then the operator should just wait for the
component to cool naturally. Boom-moving
functions continue to work during these
messages.

Operator Action messages

Tell the operator to perform some action that will
make the AB46J work correctly. The operator
should perform the action then check the display
to see that an Information message has returned.
An Information message shows the AB46J has
returned to a normal operating condition.

Service Required messages

Indicate conditions that are beyond the ability of
an operator to correct. The AB46J should be
taken out of service immediately and remain out
of service until a qualified service technician
repairs the problem. The operator should note
and report the ERROR (in the second line of the
message) to the service technician.

AB46J – 0163187

page 6 - 5

6. Controls

Electronic Display window