4. Gauges, Circuit Breakers and Displays

Gauges

Ammeter

The ammeter on the battery charger, shows the
DC charging current going to the batteries. See
the “Batteries and Battery Charging” chapter 5,
for a detailed discussion of the charging current.

Hour Meter

The Hour Meter gauge is basically an electric
clock. It accumulates time when any part of the
AB46J is in motion. Time will accumulate when
the following conditions occur simultaneously:

Battery charger is disconnected,

Battery switch . . . . . . . . . . . . . . . . . . . . . . . ON
Platform/Ground Selector . . . . . . . . GROUND
Emergency Stop (ground). . . . . . . . . . . . . . ON
Master Key Switch . . . . . . . . . . . . . . . . . . . ON
Ground Operation switch . . . . . . . . . . . . . . UP

Time will also accumulate when:

Battery charger is disconnected,

Battery switch . . . . . . . . . . . . . . . . . . . . . . . ON
Platform/Ground Selector . . . . . . PLATFORM
Emergency Stop (ground). . . . . . . . . . . . . . ON
Master Key switch . . . . . . . . . . . . . . . . . . . . ON
Emergency Stop (platform). . . . . . . . . . . . . ON
Foot Switch . . . . . . . . . . . . . . . . . . Stepped On

The hour meter gauge cannot be reset. Use it to
tell when it is time to perform the periodic
maintenance listed in the Maintenance Manual.

Hydraulic Oil Filter

The hydraulic oil filter gauge (1) is located above
the hydraulic oil filter (2). The gauge measures
pressure into the filter. As the filter clogs, the
pressure goes up.

Check the condition of the filter, at the start of
each work shift, according to the procedure
described in the “Daily Inspection and
Maintenance” chapter 7, in this manual.

AB46J – 0163187