7. Daily Inspection and Maintenance

At the start of each work day (or 8 hour shift), an
AB46J qualified operator must perform the Daily
Inspection and Maintenance as listed in the table
below.

The purpose of the Daily Inspection and
Maintenance is to keep the AB46J in proper
working condition and to detect signs of
malfunction at the earliest possible time.

The AB46J should be in the STOWED POSITION
and the Master Key Switch set to OFF before
you begin this inspection.

Defective parts and/or equipment malfunctions
jeopardize the safety of the operator and other
personnel, and can cause damage to the
machine.

DO NOT operate an AB46J that is known to
be damaged or malfunctioning.

Repair all equipment damage or malfunctions,
before placing the AB46J into service.

AB46J – 0163187

page 7 - 1

Item

Service Required

Wiring harnesses

Visually inspect (installation, condition)

Battery terminals

Visually inspect (no corrosion)

Battery fluid level

Check fluid level (in contact with filler neck)

Hydraulic oil

Visually inspect level (between lines on gauge)

Hydraulic oil leaks

Visually inspect (hoses, tubes)

Tires

Visually inspect (condition)

Bolts and fasteners

Visually inspect (condition)

Structural damage and welds

Visually inspect (weld cracks, dents)

Lanyard anchor points

Visually inspect (condition)

Platform guardrails

Visually inspect (condition)

Platform gravity gate

Check condition and operation

Platform swinging gate (option)

Check condition and operation

Flashing lights (option)

Visually inspect (operation)

Battery charger

Check operation

Ground-control box

Actuate and inspect for operation

Level sensor

Check operation

Platform-control box

Actuate and check for operation

Emergency power

Check operation (causes correct motion)

GFCI (Ground Fault Circuit Interrupt)

Check operation

Slide pads

Visually inspect for installation and boom wear marks

Hydraulic-oil filter

Check condition

Placards and decals

Visually inspect (installation, condition)

Daily Inspection and Maintenance Table