Maintenance
067449-023 LX31/LX41 Electric and BiEnergy
Operator Manual
Page 15
B
A T T E R Y
M
A I N T E N A N C E
The batteries are located in the Control Module.
Figure 10: Battery Location
W A R N I N G
!
!
Hazard of explosive gas mixture. Keep sparks, flame,
and smoking material away from battery.
Always wear safety glasses when working with batteries.
Battery fluid is highly corrosive. Thoroughly rinse away
any spilled fluid with clean water.
Always replace batteries with UpRight batteries or
manufacturer approved replacements weighing 48 kg
(106 lbs.) each.
Check battery fluid level daily, especially if the work
platform is being used in a warm, dry climate.
If the electrolyte level is lower than 10 mm (3/8 in.)
above plates, add distilled water ONLY. Do not use tap
water with high mineral content; it will shorten battery life.
The battery and cables should be inspected regularly for signs of cracks in the case, electrolyte leakage
and corrosion of the terminals. Inspect the cables for worn spots or breaks in the insulation and for broken
cable terminals.
Refer to the Service Manual to extend battery life and for complete service instructions.
BiEnergy Models include one 12 Volt Battery for
starting the engine. It is located behind the
ladder assembly
Eight 6 Volt Batteries