AEM Infinity Supported Applications - Ford Coyote Engine with Ford Racing Control Pack User Manual
Page 34
34
© 2014 AEM Performance Electronics
Infinity
Pin
Infinity Assignment
Pin
Destination
Ford Coyote with FR
Control Pack
Description
Infinity Hardware
Specification
Notes
C2-37
Digital_In_6
---
Spare Digital Input
No pullup. Will work with
TTL signals.
Input can be assigned to dif f erent
pins. See Setup Wizard page Input
Function Assignments f or input
mapping options.
C2-38
Digital_In_7
---
Brake Switch
No pullup. Will work with
TTL signals.
See BrakeSwitch 1-axis table f or
setup options. Input can be
assigned to dif f erent pins. See
Setup Wizard page 'Input Function
Assignments' f or input mapping
options.
C2-39
Power Ground
---
Ground
Power Ground
Connect directly to battery ground.
C2-40
Power Ground
---
Ground
Power Ground
Connect directly to battery ground.
C2-41
CanH_Bout
---
CANH
Dedicated High Speed
CAN Transceiv er
Not used
C2-42
CanL_Bout
---
CANL
Dedicated High Speed
CAN Transceiv er
Not used
C2-43
LowsideSwitch_8
Ford Racing
PCM70-07
Starter Motor Control
(SMC)
Lowside switch, 4A max
with internal f ly back
diode. Inductiv e load
should NOT hav e f ull
time power.
See Setup Wizard Page 'LowSide
Assignment Tables' f or
conf iguration options. See 2D table
'LS8_Duty [%]' f or activ ation
settings.
C2-44
LowsideSwitch_7
Engine
E-57
Variable Camshaf t
Timing 22 Solenoid
(Driv erside Exhaust)
Lowside switch, 4A max
with internal f ly back
diode. Inductiv e load
should NOT hav e f ull
time power.
See Setup Wizard Page 'LowSide
Assignment Tables' f or
conf iguration options. See 2D table
'LS7_Duty [%]' f or activ ation
settings. See Setup Wizard page
'VVC' f or options.
C2-45
UEGO 2 VM
---
UEGO 2 VM
Bosch UEGO Controller
Virtual Ground signal. Connect to
pin 5 of Bosch UEGO sensor.
C2-46
UEGO 2 UN
---
UEGO 2 UN
Nernst Voltage signal. Connect to
pin 1 of Bosch UEGO sensor.
C2-47
UEGO 2 IP
---
UEGO 2 IP
Pumping Current signal. Connect
to pin 6 of Bosch UEGO sensor.
C2-48
UEGO 2 IA
---
UEGO 2 IA
Trim Current signal. Connect to pin
2 of Bosch UEGO sensor.
C2-49
UEGO 2 HEAT
---
UEGO 2 HEAT
Lowside switch f or UEGO heater
control. Connect to pin 4 of Bosch
UEGO sensor. NOTE that pin 3 of
the Sensor is heater (+) and must
be power by a f used/switched 12V
supply .