Ftp settings] - [ftp tx settings, Snmp settings – Konica Minolta bizhub C3350 User Manual
Page 61
1.5
Available operations in Administrator mode
1
[Applied Functions]
1-55
[FTP Settings] - [FTP TX Settings]
To display: Administrator mode - [Network] - [FTP Settings] - [FTP TX Settings]
Configure settings to enable use of the FTP transmission function on this machine.
[SNMP Settings]
To display: Administrator mode - [Network] - [SNMP Settings] - [SNMP Settings]
Configure the settings for obtaining the machine information and monitoring the machine using SNMP (Sim-
ple Network Management Protocol).
[Command Prohibit]
Select a command to deny a receiving job from an FTP client when using the
FTP server of this machine.
Set this option to return an error when a PORT/EPRT command or PASV/EPSV
command is sent from an FTP client to this machine.
[Allow] is specified by default.
[PORT Command En-
hanced Security]
Select whether or not to enable the security of this machine against FTP
bounce attacks. This option is not available if [Command Prohibit] is set to
[PORT/EPRT].
When a PORT/EPRT command is sent from an FTP client, the data connection
is established only if both of the following conditions are satisfied:
•
A port number less than 1024 is not specified.
•
The IP address specified by the command is same as that specified when
a control connection is established.
[Enable] is specified by default.
Item
Description
Item
Description
[FTP TX]
Select whether or not to use the FTP transmission function of this machine.
Selecting this option sends the scanned original data to the FTP server.
[Enable] is specified by default.
[Connection Timeout]
If necessary, change the time-out time to limit a communication with the FTP
server.
[60] sec. is specified by default.
[Proxy Server Address]
To access to the FTP server via a proxy server, enter the proxy server address.
Use one of the following formats.
•
Example of host name entry: "host.example.com"
•
Example of IP address (IPv4) entry: "192.168.1.1"
•
Example of IP address (IPv6) entry: "fe80::220:6bff:fe10:2f16"
[Proxy Server Port
Number]
If necessary, change the proxy server port number.
[21] is specified by default.
Item
Description
[SNMP Settings]
Configure the SNMP settings.
[SNMP]
Select whether or not to use SNMP.
[Enable] is specified by default.
[SNMP v1/v2c (IP)]
Select whether or not to use SNMP v1 or SNMP v2.
[Enable] is specified by default.
[SNMP v3 (IP)]
Select whether or not to use SNMP v3.
[Enable] is specified by default.
[UDP Port]
If necessary, change the UDP port number.
[161] is specified by default.
[SNMP v1/v2c Settings]
Configure the SNMP v1/v2c settings.