An366, Figure 38. negative phase offset – Cirrus Logic AN366 User Manual

Page 42

background image

AN366

42

AN366REV2

PHASE OFFSET
PC/Controller test for phase calibration range meet or fail meter. This example shows neg-
ative phase offset.

Figure 38. Negative Phase Offset

PHASE OFFSET
PC/Controller test for coarse phase calibration range.

When > 1 OWR, PC/Controller calculates Coarse Compensation

CPCC1 = 0
CPCC2 = 0

PC/Controller calculates Fine Compensation

FPCC1 = -(-0.55224327) / 0.008789 @ 50Hz = 62,
FPCC2 = -(-0.57051489) / 0.008789 @ 50Hz = 64,

CPCC1=0, FPCC1 = 62, CPCC2=0, FPCC2 = 64
SDI =

0x80 0x45 0x007C40

Write Phase Comp

(page 0, register 69)

SDO = 0xFF 0xFF 0xFFFFFF

SDI = 0x80

0x05 0xFFFFFF

Write Phase Comp (page 0, register 69)

SDO = 0xFF

0xFF 0x007C40

-8.99º <

PHASE OFFSET

< +8.99º ? (50Hz)

PHASE OFFSET

NEGATIVE?

-512 · 0.008789 <

PHASE OFFSET

< 0 (50Hz)

?

FINE

COMPENSATION

(FPCC) = -PHASE

OFFSET ÷

0.008789 (50Hz)

SET COARSE

COMPENSATION

(CPCC = 01)

1 OWR on I

PHASE OFFSET =
PHASE OFFSET +

4.5º (50Hz)

±10.79º @ 60Hz

0 to 512 · 0.010547 @ 60Hz

5.4º @ 60Hz

0.010547 @ 60Hz

FAIL

METER

2

YES

NO

YES

NO

3

YES

Example Location

Before Calibration V is delayed from I

Delay added to I

8.99º @ 50Hz

10.79º @ 60Hz

4.5º @ 50Hz
5.4º @ 60Hz

-4.5º @ 50Hz
-5.4º @ 60Hz

-8.99º @ 50Hz

-10.79º @ 60Hz