Kramer protocol – Kramer Electronics VP-81KSi User Manual
Page 42

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol
38
Signal Status commands
Command
Syntax
Response
Change signal status
-------------------
SIGNAL INPUT, STATUS
Get signal status
SIGNAL? INPUT
SIGNAL INPUT, STATUS
Parameters Description:
INPUT = Input number, ‘*’ for all.
STATUS = Signal state:
"0" or "off" for not existent signal.
"1" or "on" for existent signal.
Preset commands
Command
Syntax
Response
Store current
connections to preset
PRST-STO PRESET
Short form: PSTO PRESET
PRST-STO PRESET RESULT
Recall saved preset
PRST-RCL PRESET
Short form: PRCL PRESET
PRST-RCL PRESET RESULT
Delete saved preset
PRST-DEL PRESET
Short form: PDEL PRESET
PRST-DEL PRESET RESULT
Read video connections
from saved preset
PRST-VID? PRESET,OUT
Short form: PVID? PRESET,OUT
PRST-VID? PRESET, *
PRST-VID PRESET, IN>OUT
PRST-VID PRESET, IN>1, IN>2,…
Read audio connections
from saved preset
PRST-AUD? PRESET,OUT
Short form: PAUD? PRESET,OUT
PRST-AUD? PRESET, *
PRST-AUD PRESET: IN>OUT
PRST-AUD PRESET: IN>1, IN>2,…
Read saved presets list
PRST-LST?
Short form: PLST?
PRST-LST PRESET, PRESET, …
Parameters Description:
PRESET = Preset number.
OUT = Output in preset to show for, '*' for all.
Examples:
Store current Audio & Video
connections to preset 5
#PRST-STR 5
CR
~PRST-STR 5 OK
CRLF
Recall Audio & Video connections
from preset 3
#PRCL 3
CR
~PRST-RCL 3 OK
CRLF
Show source of video output 2 from
preset 3
#PRST-VID? 3,2
CR
~PRST-VID 3: 4>2
CRLF