Shut down the pump, Deactivate the i-alert™ condition monitor, Reset the i-alert™ condition monitor – Goulds Pumps 3393 - IOM User Manual
Page 48: Make the final alignment of the pump and driver

Commissioning, Startup, Operation, and Shutdown
Shut down the pump
WARNING:
The pump can handle hazardous and toxic fluids. Identify the contents of the pump and observe proper
decontamination procedures in order to eliminate the possible exposure to any hazardous or toxic fluids.
Wear the proper personal protective equipment. Potential hazards include, but are not limited to, high
temperature, flammable, acidic, caustic, explosive, and other risks. You must handle and dispose of
pumped fluid in compliance with the applicable environmental regulations.
1. Slowly close the discharge valve.
2. Shut down and lock the driver to prevent accidental rotation.
3. Bring the pump to a complete stop within 5 seconds.
Deactivate the i-ALERT™ Condition Monitor
NOTICE:
Always deactivate the condition monitor when the pump is going to be shut down for an
extended period of time. Failure to do so will result in reduced battery life.
1. Touch and hold a small magnet to the condition monitor over the ITT logo until the red
LEDs blink three times.
This should take 10-15 seconds if the condition monitor is in normal operating mode and
approximately five seconds if the condition monitor is in alarm mode.
2. Remove the magnet.
If the deactivation is successful, solid red LEDs will be displayed.
Reset the i-ALERT™ Condition Monitor
NOTICE:
Always reset the condition monitor when the pump is started after maintenance, system
change, or down-time. Failure to do so may result in false baseline levels that could cause the
condition monitor to alert in error.
1. Touch a magnet to the condition monitor over the ITT logo to turn the power on.The
condition monitor begins to establish a new baseline vibration level.
Make the final alignment of the pump and driver
Alignment procedures must be followed to prevent unintended contact of rotating parts.
Follow coupling manufacturer's installation and operation procedures.
WARNING:
• Always disconnect and lock out power to the driver before you perform any installation or
maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.
• Follow shaft alignment procedures in order to prevent catastrophic failure of drive components or
unintended contact of rotating parts. Follow the coupling installation and operation procedures from
the coupling manufacturer.
You must check the final alignment after the pump and driver are at operating temperature. For
initial alignment instructions, see the Installation chapter.
1. Run the unit under actual operating conditions for enough time to bring the pump, driver,
and associated system to operating temperature.
2. Shut down the pump and the driver.
46
Model 3393 Installation, Operation, and Maintenance Manual