Installation

NOTICE:A positive value indicates that the pump shaft should be set higher than the motor
shaft; a negative value indicates that the pump shaft should be set lower than the motor shaft.

Table 3: Pump operating temperature for 2.5x4-8 and 2.5x5-8

Motor Temperature

English units (inches)

Metric units (mm)

Rise

<100

o

F

100-

201-

301-400

o

F <38

o

C

38-93

o

C 94-

150-

200

o

F

300

o

F

149

o

C

204

o

C

104

o

F (40

o

C)

0.004

0.000

-0.009

-0.018

0.11

0.00

-0.23

-0.46

122

o

F (50

o

C)

0.006

0.001

-0.007

-0.017

0.15

0.04

-0.19

-0.42

Table 4: Pump operating temperature for 4x5-10 and 4x6-10

Motor Temperature

English units (inches)

Metric units (mm)

Rise

<100

o

F

100-

201-

301-

<38

o

C

38-

94-149

o

C 150-

200

o

F

300

o

F

400

o

F

93

o

C

204

o

C

104

o

F (40

o

C)

0.005

0.000

-0.010

-0.021

0.13

0.00

-0.26

-0.53

122

o

F (50

o

C)

0.007

0.002

-0.009

-0.019

0.17

0.04

-0.22

-0.48

Table 5: Pump operating temperature for 5x6-11 and 5x8-11

Motor Temperature

English units (inches)

Metric units (mm)

Rise

<100

o

F

100-

201-

301-400

o

F <38

o

C

38-93

o

C 94-

150-

200

o

F

300

o

F

149

o

C

204

o

C

104

o

F (40

o

C)

0.006

0.000

-0.012

-0.023

0.14

-0.01

-0.30

-0.59

122

o

F (50

o

C)

0.008

0.002

-0.010

-0.021

0.20

0.05

-0.24

-0.54

Table 6: Pump operating temperature for 6x8-13 and 6x10-13

Motor Temperature

English units (inches)

Metric units (mm)

Rise

<100

o

F

100-

201-

301-

<38

o

C

38-

94-149

o

C 150-

200

o

F

300

o

F

400

o

F

93

o

C

204

o

C

104

o

F (40

o

C)

0.006

0.000

-0.013

-0.027

0.16

-0.01

-0.34

-0.68

122

o

F (50

o

C)

0.009

0.002

-0.011

-0.024

0.22

0.05

-0.28

-0.62

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver

This prevents incorrect measurement.

coupling half together so that the indicator rods
have contact with the same points on the driver
coupling half.
Move or shim only the driver in order to make

This prevents strain on the piping installations.

adjustments.
Make sure that the hold-down bolts for the driver

This keeps the driver stationary since movement

feet are tight when you take indicator measure-

causes incorrect measurement.

ments.
Make sure that the hold-down bolts for the driver

This makes it possible to move the driver when you

feet are loose before you make alignment correc-

make alignment corrections.

tions.
Check the alignment again after any mechanical

This corrects any misalignments that an adjustment

adjustments.

may have caused.

Attach the dial indicators for alignment

You must have two dial indicators in order to complete this procedure.
1. Attach two dial indicators on the pump coupling half (X):

a) Attach one indicator (P) so that the indicator rod comes into contact with the perimeter

of the driver coupling half (Y).
This indicator is used to measure parallel misalignment.

Model 3393 Installation, Operation, and Maintenance Manual

25