Troubleshooting
Troubleshooting
Alignment troubleshooting
Symptom
Cause
Remedy
Horizontal (side-to-side) alignment cannot The driver feet are bolt-bound.
Loosen the pump's hold-down bolts, and
be obtained (angular or parallel).
slide the pump and driver until you
achieve horizontal alignment.
The baseplate is not leveled properly and 1. Determine which corners of the base-
is probably twisted.
plate are high or low.
2.
Remove or add shims at the appropri-
ate corners.
3.
Realign the pump and driver.
i-ALERT™ Condition Monitor troubleshooting
Symptom
Cause
Remedy
There are no green or red flashing LEDs.
The battery is dead.
Replace the condition monitor.
The unit is deactivated.
Activate the condition monitor.
The unit is malfunctioning.
Consult your ITT representative
for a warranty replacement.
The red LEDs are flashing, but the temperature and
The baseline is bad.
Check the temperature and vi-
vibration are at acceptable levels.
bration levels and reset the con-
dition monitor.
The unit is malfunctioning.
Consult your ITT representative
for a warranty replacement.