C-face adapter inspection, Seal chamber and stuffing box cover inspection – Goulds Pumps 3196 i-FRAME - IOM User Manual
Page 91

Maintenance
This figure shows the areas to inspect for wear on the bearing frame inside surface.
Figure 21: Inside surface inspection locations
C-face adapter inspection
Checklist
• Visually inspect the C-face adapter (340) for cracks.
• Check all surfaces for rust, scale, or debris and remove all loose and foreign material.
• Check for corrosion or pitting.
This figure shows the areas to inspect for cracks on the C-face adapter.
Figure 22: C-face adapter inspection locations
Seal chamber and stuffing box cover inspection
Checklist
Perform these checks when you inspect the seal chamber and stuffing box cover:
• Make sure that these surfaces are clean:
• Seal chamber and stuffing box cover
• Dynamic-seal backplate gasket
• Mounting
• Make sure there is no pitting or wear greater than 1/8 in. (3.2 mm) deep.
Replace the seal chamber and stuffing box cover if pitting or wear exceeds this
measurement.
• Inspect the machined surfaces and mating faces noted in the figures.
These images point to the areas to inspect:
Model 3196 i-FRAME Installation, Operation, and Maintenance Manual
89