Goulds Pumps 3196 i-FRAME - IOM User Manual
Page 130

Maintenance
This table shows which brand of grease to use when lubricating the pump.
Pumpage temperature less than Pumpage temperature greater
350°F (177°C)
than 350°F (177°C)
NGLI consistency
2
3
Mobil
Mobilux EP2
SCH32
Exxon
Unirex N2
Unirex N3
Sunoco
Mutipurpose 2EP
N/A
SKF
LGMT 2
LGMT 3
Convert from greased-for-life or regreaseable to oil-lubricated bearings
1. Remove the plug from the oil-return slot in the frame located under the radial bearing. Use
this table as a guide.
Pump model
Action
STi
Remove the epoxy from the return slot.
MTi, LTi, XLT-i, and i-17
Remove the set screw installed in the oil-return hole.
2. Remove the plug from the oil-return hole in the bearing housing (134).
3. Replace both bearings with unshielded, oil-lubricated bearings.
Table 24: Bearing types
Outboard bearing
Frame
Inboard bearing
Double row
Duplex
STi
6207
3306
7306
MTi
6309
3309
7309
LTi
6311
Not applicable
7310
XLT-i, i17
6313
3313
7313
4. Remove the grease fittings (193) to prevent accidental greasing.
Two plugs (408H) are required to replace the two grease fittings.
Item Number
Size
Description
Quantity
113
1/4"-18 NPT
External hex/square
2
head pipe plug
113A
1/2"-14 NPT
External hex/square
1
head pipe plug
193
1/4"-18 NPT
Grease fitting
2
228
- - - -
Bearing frame
1
241
- - - -
Frame foot
1
370F
1/2"
Hex cap screw
2
128
Model 3196 i-FRAME Installation, Operation, and Maintenance Manual