Bearing lubrication, Oil volumes – Goulds Pumps 3196 i-FRAME - IOM User Manual
Page 52

Commissioning, Startup, Operation, and Shutdown
9. Slide the driver-half of the coupling guard towards the motor so that the coupling guard
completely covers the shafts and coupling.
10. Use a nut, a bolt, and two washers to secure the coupling guard halves together.
11. Tighten all nuts on the guard assembly.
WARNING:
Never operate the pump without the coupling guard correctly installed.
Bearing lubrication
WARNING:
Make sure to properly lubricate the bearings. Failure to do so can result in excess heat generation,
sparks, and premature failure.
NOTICE: Be certain to check the greasing on a pump that has been out of service for a long
period of time and re-grease if necessary.
Pumps are shipped without oil. You must lubricate oil-lubricated bearings at the job site.
Grease-lubricated bearings are lubricated at the factory.
The bearing manufacturer fills greased-for-life bearings with grease and seals them at the
factory. You do not need to lubricate or seal these bearings.
Oil volumes
Oil volume requirements
This table shows the required amount of oil for oil-lubricated bearings.
Frame
Qts.
Oz.
ml
STi
0.5
16
400
MTi
1.5
47
1400
LTi
1.5
48
1400
XLT-i and i17
3
96
3000
50